Complete Roofing Solutions for Tornado
We've been providing roofing services to Tornado homeowners and businesses for 18 years. From repairs to full replacements. It's all we do, and we do it right.
Roof Replacement
Your roof replacement includes a full-system install: ice and water shield at eaves, valleys, and penetrations; synthetic underlayment across the entire deck; aluminum drip edge at rake and eave; starter strip with sealant; architectural shingles with 130+ mph wind rating; and continuous ridge vent for proper attic ventilation. We also install new pipe boots and vent flashing on every penetration.
Get a Free Quote โRoof Repair
Improper step flashing is the leading cause of roof leaks at wall-to-roof transitions. Step flashing needs to be woven between shingle courses with each piece extending 4" above the shingle exposure. We see Tornado homes where the last roofer used continuous L-flashing or just caulked the gap. That always fails. We tear it out and install proper step flashing with a kick-out diverter at the bottom per IRC R905.2.8.3.
Get a Free Quote โStorm Damage Repair
Wind damage and hail damage look different and require different documentation. Our HAAG-trained inspectors know what adjusters look for: granule displacement patterns, fractures in the shingle mat, seal failures, cracked ridge caps. Proper documentation is why our claims get approved.
Get a Free Quote โNew Roof Installation
We install new roofs on new homes, additions, detached garages, carports, and covered patios. Material options include asphalt architectural shingles, metal standing seam, metal corrugated, and flat membrane systems. We help you choose based on your budget, aesthetic preference, and the specific demands of your Tornado climate.
Get a Free Quote โMetal Roofing
Metal roofing reflects solar heat instead of absorbing it. In West Virginia, that means 15-25% lower cooling costs compared to dark asphalt shingles. The higher upfront cost pays for itself over the life of the roof. And the life of a metal roof is twice or three times longer than shingles.
Get a Free Quote โShingle Roofing
GAF Timberline HDZ. The best-selling shingle in North America. With StrikeZone nailing area for consistent fastener placement. Class A fire rating per UL 790, Class 4 impact resistance per UL 2218 (when installed in the GAF Roof System), and Class H wind rating per ASTM D7158 (130 mph). We install Timberline in the full GAF system to qualify for Golden Pledge warranty: 25-year non-prorated workmanship plus 50-year materials with WindProven limited wind warranty (no max speed). That warranty is why we recommend GAF for most Tornado homes.
Get a Free Quote โFlat Roofing
PVC membrane for Tornado restaurants, commercial kitchens, and facilities with rooftop grease exhaust or chemical exposure. PVC resists oils and animal fats that destroy TPO and EPDM membranes. We install IB Roof Systems and Duro-Last PVC with factory-fabricated accessories for watertight penetration details. Built-up roofing (BUR) uses 3 or 4 plies of fiberglass felt in hot asphalt with a gravel or cap sheet surface. Oldest proven flat roof system, with 30+ year service life in West Virginia. We still install BUR when the application calls for it.
Get a Free Quote โCommercial Roofing
We install Carlisle SynTec and Firestone TPO membrane systems in 60-mil and 80-mil thickness over minimum R-25 polyiso insulation (more in climate zones requiring it). Seams hot-air welded at 900ยฐF+ and tested with a seam probe. Fully adhered systems for wind uplift zones per FM I-90 or I-120. Mechanically attached for re-roofs over existing insulation. NRCA member, trained per manufacturer specifications.
Get a Free Quote โGutter Installation
Gutter replacement in Tornado costs $8-$15 per linear foot installed. That includes hangers, end caps, outlet drops, miters, and at least two downspout runs. Copper is $25-$40 per foot. We give exact pricing in the estimate. No ranges.
Get a Free Quote โRoof Inspection
Commercial and flat roof inspections include infrared moisture scanning with Flir E8 thermal cameras. Trapped moisture in the insulation layer shows as temperature differentials on the thermal image. No need to cut core samples everywhere. We identify wet zones, then core sample the suspect areas to confirm. This approach gives you a precise repair scope at a fraction of the cost of exploratory tear-offs.
Get a Free Quote โEmergency Roof Repair
Emergency tarping is step one. Stop the water. We secure heavy-duty poly tarps over the damaged area using 2x4 nailer boards attached to the deck. Once the immediate threat is contained, we schedule the permanent repair within 48-72 hours.
Get a Free Quote โSkylight Installation
VELUX FS (fixed) and VS (vented) skylights installed with EDL flashing kits for shingle roofs. The multi-step flashing integrates with the surrounding shingle courses per IRC R903.2. We frame the curb with doubled 2x8 or 2x10 lumber (depending on rafter depth), install ice and water shield membrane around the entire curb perimeter, then set the skylight with factory sealant before weaving step flashing into the field. Top headwall flashing tucks under the upslope shingle course. Bottom sill pan diverts water onto the downslope shingles. Zero exposed sealant joints. Mechanical flashing only.
Get a Free Quote โ